11jan2011 22648 miles, recharged pack, +4.98kwh, 11.88kwh total, no o/c time. Refilled bearing reservoir with Mobile1.
10jan2011 Flattened entire pack. Jumpered redtop cells.
10jan2011 drove deep discharge, -6.90kwh.

Watered entire pack, 22627 miles, many cells very low. 3.7 gallons H20.

Set charger to 2 minutes of constant voltage time.

10jan2011 22627 miles, watered entire pack. Many cells very low. 3.7 gallons H20.

09jan2011 Drove, deep discharge, -6.93kwh, recharged 2.77kwh, 9.70kwh total. Pack was very stiff during charging and driving.
09jan2011 Recharged flattened pack, +5.88kwh, 11.18kwh total. 20 cells appeared shorted. After 30 minutes of charging they all appeared normal. Cells are marked with a red circle on their cap.
08jan2011 Flattened entire pack, -5.30kwh, 18.9ah, 19.1miles, 11:35pm.

07jan2011 Recharge.+2.94kwh, 8.73kwh total.
06jan2011 Drove deep discharge,-5.79kwh

06jan2011 Recharge, +2.18kwh, 6.53kwh total.
05jan2011 Drove deep discharge, -4.35kwh

27dec2010 Added 10 used and tested nicad cells to pack. 251 total. Set charge voltage to 400vdc.

16dec2010 +3.86kwh (8.3ah) on recharge. 11.19kwh (35.7ah) total recharge.

15dec2010 +4.55kwh on recharge. 11.59kwh total recharge.

15dec2010 -7.33kwh (27.4ah) @ 30.1 miles, 244.3wh/mi, dry, sunny, warm. Errands, highway and city driving. Heater. SJ loop.

14dec2010 -7.04kwh @ 27.7 miles, 254wh/mi, raining, cold, dark, no no heater. SJ loop.

241 cells installed. 2 shorted green top cells removed. 24 Redtops watered. 3 clear tops watered.

27nov2010 -4.55kwh, 20.3 miles, 243wh/mi

26nov2010 -4.13kwh, 15.55 miles, 265wh/mi